Outdated ERP and MES servers in an industrial IT environment as a symbol of legacy systems and historical corporate data
Korbinian Hermann23.11.202622 min read

Replacing Legacy Systems: Risks, Costs and the Safe Path to Shutdown

In short

Replacing a legacy system means taking an outdated application out of service without losing access to its data. Active data moves to the successor system, data subject to retention is archived in an audit proof way. The legacy system can then be shut down, because the retention obligation applies to the content, not the application.

In almost every manufacturing company there is a system that nobody needs any more and nobody is allowed to switch off. It no longer does anything useful, the processes moved long ago. And yet IT renews the database licence every year, the server still sits in the rack, and everything depends on the one colleague who still understands the system and retires in two years.

The reason it keeps running is rarely technical. It is the fear of no longer being able to access your own data. Because that is where historical orders, production data, test results, audit trails and tax relevant information sit, and they must remain available. The system has to go, the data has to stay.

This guide shows how to recognise a legacy system that is ready to be replaced, what continued operation really costs, which of the three paths fits your situation and how to shut down a legacy system in five stages without losing data or audit readiness. How CHRONOS approaches this is shown on the CHRONOS website.

Key facts

  • A legacy system is not a question of age, but of the ratio between business critical importance and limited maintainability.
  • The six clearest warning signs are missing vendor support, dependence on individual people, expensive special licences, missing interfaces, unpatched security gaps and media breaks to other systems.
  • There are three paths for a legacy system: migration, data transfer with decommissioning, or audit proof archiving followed by shutting down the application. The decision is made per data area, not per system.
  • A backup does not replace a decommissioning. It secures systems, not information, and does not provide evaluable access in an audit.
  • Retention obligations under § 147 AO, the GoBD, IATF 16949 and customer requirements can be met without keeping the legacy system alive.

In a nutshell

Recognise

Several warning signs together make a system ready for replacement. The risk class determines the urgency, not the age.

Decide

Decide per data area: migrate, archive or delete. The history does not have to go into the new system.

Archive

Transfer data subject to retention into an open, audit proof archive that can be evaluated without the legacy system.

Shut down

Set the end date in advance, obtain business acceptance, then shut down in a controlled way and cancel licences.

 

01 · Basics

What is a legacy system?

A legacy system is an outdated software application that is still in productive use although its technology, maintenance model or integration capability no longer meets current standards. The term does not describe a point in time, but a ratio: business critical importance on the one hand, limited maintainability on the other.

That is why age is a misleading criterion. A twenty year old system that is properly maintained, has documented interfaces and is supported by its vendor is not a legacy system. A five year old system without support, without connectivity and with exactly one person in the company who understands it can already be one. With every year of delay, technical debt grows: every adjustment becomes a risk, every update a gamble.

In manufacturing, this typically applies to four categories:

  • process databases that have grown over years and hold measured values in proprietary structures
  • older MES and CAQ applications on database platforms that are no longer supported
  • proprietary machine control and data acquisition systems from individual equipment manufacturers
  • in house island solutions whose developers left the company long ago

These systems almost always hold exactly the data that must remain available in the long term for compliance reasons. And that is the only reason they keep running. This is the core of the problem and at the same time the starting point for the solution.

44 %

of companies surveyed classify at least half of their existing systems as legacy systems

Source: Legacy Modernisation Study 2022, CIO and Computerwoche

almost 50 %

of German speaking SAP users want to keep running ECC beyond 2027

Source: DSAG survey February 2026, according to cloudmagazin

8 years

retention for accounting vouchers since 1 January 2025

Source: § 147(3) AO

5 calendar years

after a system change, full evaluability remains mandatory

Source: § 147(6) AO

 

02 · Warning signs

How do you recognise a legacy system ready for replacement?

Not every older system has to be replaced. What matters is whether several warning signs coincide. A single sign is no reason to act; three or more are.

1

Sign 1

No more vendor support

Security updates and bug fixes stop, the system remains frozen at its last version.

2

Sign 2

Dependence on individual people

Only one or two employees still understand the system. When they leave, knowledge is lost for good.

3

Sign 3

Expensive special licences

Database or runtime licences cause high annual costs without creating any new value.

4

Sign 4

Missing interfaces

The system cannot be connected to ERP, MES or modern analytics tools, or only via workarounds.

5

Sign 5

Security gaps without a patch

Known vulnerabilities remain open because the vendor no longer delivers fixes.

6

Sign 6

Media breaks

Data has to be transferred, exported or retyped manually. This creates error risks and effort.

The warning signs reinforce each other. Missing support leads to security gaps, security gaps lead to the system being isolated in the network, isolation leads to media breaks, and media breaks tie up staff. The risk class shows how urgently you need to act:

Risk classes of legacy systems in production

Risk level Indicators Consequence Recommendation
Critical no vendor support, operating system without security updates every network connection is a potential entry point start the shutdown plan immediately
High support expired, only basic updates, no connection to new systems isolated operation, rising costs, interface problems start the shutdown plan within a year
Medium vendor active, system at the end of its life cycle, successor defined growing complexity, knowledge held by few people plan the migration
Low functional, vendor active, not strategically viable no immediate risk include in investment planning

Under NIS2 in particular, an unpatched legacy system quickly becomes a compliance question. How manufacturers deal with this is described in the article NIS2 and legacy systems.

 

03 · Reasons

Why do legacy systems keep running although they no longer do anything useful?

The most common state is not the actively used legacy system, but read only operation: the processes run in the new system, the old one stays on because the history is stored in it. In practice, the reason is almost always the same: nobody knows exactly what is in the system. As long as that is unclear, nobody switches it off.

Common reasons against shutting down and what lies behind them

Reason What lies behind it
“We need the historical data.” justified, but data can be archived; the system does not have to run for that
“It runs stably, we don't touch it.” without security updates, stability is a silent risk
“We have no time for a migration.” unplanned continued operation also costs money and capacity every year
“Some processes still depend on it.” solvable, but only if the interfaces are actively inventoried
“We don't know how to get the data out.” most databases can be read out, even without a documented interface

Then there is the compliance side. When a regulatory or audit request comes in, the search begins in legacy systems, exports and spreadsheets. In practice, that is a research task of days to weeks. The legacy system does not create the ability to provide information, it only simulates it. And the right time to shut down never comes: there is always an ongoing project, an upcoming audit or a change in personnel.

“

The most expensive decision in the IT architecture of a manufacturing company is not the new system. It is the old one that could not be switched off and therefore runs alongside the new one for another three years, not really looked after by anyone, but feared by everyone.

Amadeus Lederle

Chief Technology Evangelist, CSP Intelligence GmbH

 

04 · Costs

What does a legacy system really cost?

The visible costs of a legacy system are only part of the bill, and usually the smaller part. Far more significant are the items that do not appear on any licence invoice and therefore never come up in a budget discussion.

Visible and hidden cost items of a legacy system

Cost type Visibility Concrete example Eliminated after archiving?
Database licence visible Annual maintenance for Oracle, SQL Server, DB2 or Informix Yes
Application licence visible Maintenance contract or extended support from the vendor Yes
Infrastructure visible Servers, storage, backup and virtualisation for a rarely used system Yes
Tied up IT staff hidden Specialist knowledge not available for further development Yes
Research effort for audits hidden Days to weeks per regulatory or audit request Yes, retrieval directly in the archive
Opportunity costs hidden Blocked modernisation, delayed cloud and ERP projects Yes
Risk costs hidden Possible outages, compliance violations, data loss largely
Archive new Storage and operation of the archive No, but considerably lower

Based on CSP project experience, continued operation of a business application or ERP module to be replaced quickly costs 50,000 to 200,000 euros per year. If several legacy systems only run as data containers, this quickly adds up to a seven figure amount per year. There are no reliable industry averages because system landscapes differ too much. Only your own calculation is reliable.

The biggest single lever: database licences

Many legacy applications rely on licensed databases whose costs continue even when the system no longer does anything useful. Pure retention, however, does not require a highly available production database. Once the holdings are transferred to an open, audit proof archive, there is no need to keep running the original database and its licences.

Do your own calculation

Compare three figures: the ongoing costs of continued operation, the risk of an unplanned outage and the one off costs of the replacement.

Project the ongoing costs over the remaining service life and the retention periods. What it costs when records are missing altogether is described in the article The cost of not archiving.

 

05 · Risks

What risks does continued operation create?

Continued operation of a legacy system creates three risk classes that reinforce each other. Maintenance risks arise because spare parts, expertise and vendor support disappear. Security risks arise because unpatched systems are vulnerable and no longer fit into modern protection concepts. Compliance risks arise because documentation obligations become ever harder to meet with an unstable system that hardly anyone can operate.

Risks of continued operation and their impact

Risk Typical problem Impact
Cybersecurity no security updates, outdated operating systems increased risk of attack
Compliance historical data not available in an auditable form audit and fine risks
Operating costs old infrastructure and specialist knowledge required high maintenance and licence costs
Data access proprietary data formats historical information no longer readable
Digitalisation missing interfaces delayed modernisation
ERP and MES migrations historical data remains in the legacy system parallel operation for years

What distinguishes this from other IT risks is how it develops over time. The risk of a legacy system does not decrease by waiting, nor does it stay constant. It grows, because support, knowledge and spare parts availability only move in one direction.

 

06 · Decision

Migrate, archive or keep running: which path fits?

Which path fits depends on a single question: is the business function still needed, or only the data? The decision is made per data area, not per system. In practice, two paths are often used in parallel within one project.

Decision matrix: migrate, archive or keep running

Criterion Migrate fully Archive and decommission Keep running
Data is needed in daily business Yes, open items and master data No, read access only No
Data model fits the target system required not required not relevant
Effort high, mapping of every table medium, one off export with validation low at first, rising over the years
Ongoing costs storage in the target system archive storage licence, hardware, operation
Security risk low low rises with the age of the system
Typical use active master data, open orders closed financial years, test and process data transition phase of a few months

The most common planning mistake is assuming it always has to be a full migration. Migrating historical data into a new ERP or MES is expensive, lengthens the project and creates data in the target system that nobody needs there. It usually comes down to a combination: active master and transaction data moves to the new system, the history moves to the archive.

Whitepaper · Data Governance

Retain, erase, prove.

Retention is not a storage problem. It is an access problem with a duty of proof.

Download the whitepaper
 

07 · Distinction

Why is a backup not a decommissioning?

Many companies consider the problem solved as soon as a backup exists. This is the most common and most expensive misconception when replacing legacy systems. A backup secures a system. Archiving secures information. Without the application logic that interprets field names and resolves relationships, a database backup can no longer be evaluated. The data exists technically, but can no longer be used in practice.

Backup and audit proof archiving compared

Criterion Backup Audit proof archiving
Purpose recovery of a system long term availability of information
Format mostly proprietary and system bound readable in the long term, system independent
Immutability not guaranteed assured and logged
Access in an audit only by restoring the system targeted query of individual transactions
Time horizon short to medium term years to decades

Only one consequence matters for the replacement: a backup does not make a legacy system ready to be shut down. It only makes shutting it down less dangerous. The detailed distinction is covered in the article Backup vs. archiving.

 

08 · Approach

How do you shut down a legacy system in five stages?

The plan is sequential: each stage is completed and accepted before the next one begins. Skipping a stage risks data loss or unplanned additional costs.

1

Stage 1

Complete inventory

Document the database schema, record users and permissions, identify all incoming and outgoing interfaces, quantify data volume and period, flag categories subject to retention. This stage is the one most often underestimated.

2

Stage 2

Classification and planning

Assign every data category to one of three classes: migration to the successor system, long term archiving or deletion in line with data protection. Check retention obligations per category, plan a test migration and a fallback scenario.

3

Stage 3

Migration and archiving

Test migration with a sample, then step by step production migration. Have every category accepted by the business, not just technically. Switch interfaces, archive data subject to retention in open formats.

4

Stage 4

Parallel operation with an end date

Set the end date bindingly in advance. Compare the results of both systems, use the legacy system read only. At the end, a clear decision based on defined criteria.

5

Stage 5

Shutdown and documentation

Secure the final export, deactivate the system in a controlled way, create a closing report with approvals, monitor the successor system, cancel licences and release hardware.

The real milestone

The critical point is the acceptance in stage 3. A data transfer is only considered successful once completeness and readability have been proven and documented against defined test rules.

Without this record, the shutdown remains a question of trust, and questions of trust are decided in favour of continued operation. How to prove the completeness of an archive with count comparison, totals comparison, checksums and a business sample check is described in the article Audit proof archiving in practice.

 

09 · Data

Which data is migrated and which is archived?

The most important content decision is: which data moves to the successor system, which is archived and which is deleted? It is relevant technically, operationally and legally.

Data categories and their target in the replacement

Category Content Target
Master data articles, materials, tools, station parameters, inspection plans full migration before go live
Ongoing transactions open orders, running batches, active inspections full migration, no shutdown during ongoing transactions
Historical process data closed batch logs, parameters of past orders migrate recent data, archive older data
Quality data subject to retention test results, releases, complaints, logs auditable long term archiving for the applicable period
Tax relevant data postings, vouchers, related master data archiving, machine evaluable according to the GoBD
Users and permissions accounts, rights, editing history rebuild the permission concept, archive the history
Personal data without retention obligation worker IDs, contact data delete before archiving (Art. 5(1)(e) GDPR)
Technical auxiliary data temporary tables, session data, caches do not archive

What an auditable archive must deliver

Open format

No proprietary binary format, but for example PDF/A for reports, CSV with a documented schema or XML with schema validation.

Completeness

Data plus metadata such as timestamps, source system, export time, table relationships and code lists.

Integrity

Checksums for all archive files, for example SHA 256, so that later changes become visible.

Retrievability

A structure in which business departments can find data on a part or batch without IT knowledge. More in the article Archive access without an IT ticket.

Archived data must also be deletable later as soon as its retention period has expired. An archive without a deletion concept becomes a legacy system itself after a few years.

 

10 · Obligations

Which obligations continue after shutdown?

The legacy system has been shut down, the data has been archived. What many forget: the retention obligations, the obligation to keep data readable and the responsibility for its integrity continue.

Obligations that continue after shutdown

Regulation What applies Period
§ 147 AO, § 257 HGB tax and commercial records, electronically available, readable and machine evaluable (§ 147(2) no. 2 AO) 10 years for books, 8 years for accounting vouchers, 6 years for commercial letters
§ 147(6) AO after a system change, a machine readable and evaluable data carrier is sufficient once the fifth calendar year has expired, provided no tax audit has begun from the sixth year after the change
IATF 16949, section 7.5.3.2.1 retain production part approvals, tooling records, product and process design records, purchase orders and contracts active product life plus one calendar year, unless customer or authority specify otherwise
Directive (EU) 2024/2853 production data can serve as exculpatory evidence claims expire 10 years after placing on the market, 25 years for latent personal injury
GDPR personal data such as user IDs and worker logs deletion once the purpose no longer applies, with proof

In the first five years after decommissioning, the archive must allow evaluations equivalent to access to the legacy system. A pure data export, a PDF or a printout is not sufficient in this phase. The five year rule, the access types Z1 to Z3 and a worked example are described in the article Shutting down legacy systems while meeting retention obligations.

“

When we come into a production facility that has just replaced a system, the first question is always: can you show me the part file for a lot from the year before the migration? The answer says everything about how well the migration was prepared.

Amadeus Lederle

Chief Technology Evangelist, CSP Intelligence GmbH

This section provides an overview and does not replace legal advice.

 

11 · Mistakes

Which mistakes put the replacement at risk?

Each of the following mistakes can mean that a system that has already been shut down has to be restarted for an audit, if that is even still possible.

1

Mistake 1

Migration without a complete inventory

“We transferred the most important data”, but nobody systematically determined what is important. The gaps only show up in an audit or a complaint.

2

Mistake 2

Backup as an archive

A database dump in the format of the legacy system can only be restored with a matching database version and application. After a few years, one of the two is missing.

3

Mistake 3

Export without metadata

Tables without field descriptions and code lists can no longer be read once the knowledge holders have left the company.

4

Mistake 4

Parallel operation without an end date

If the legacy system keeps running “just to be safe”, two data states and conflicts arise. The end date is fixed before the start, extensions only in writing.

5

Mistake 5

No business acceptance

IT reports “fully transferred”, but quality and accounting never checked the data. Every category needs acceptance by the business department.

6

Mistake 6

Overlooked interfaces

ERP, reporting or certificate generation pull data from the legacy system without it being documented. Also record data flows that only work “somehow”.

Self check: can your legacy system be shut down?

☐We know which data from the legacy system is still needed, per data area.

☐The retention period is documented for every data area.

☐Historical data can be read and evaluated independently of the source system.

☐Backup strategy and archiving strategy are clearly separated.

☐A deletion concept aligns tax retention periods and GDPR obligations.

☐An auditor could retrieve a single transaction from 2015 without a restore.

☐The data transfer can be accepted and documented against defined test rules.

☐After shutdown, the database licence of the legacy system is actually cancelled.

The more points remain open, the more likely the legacy system will keep running in the next budget year as well. The open points are also your work list.

Next step

Is your legacy system ready to be shut down?

Together we check where your legacy system stands and which data needs to be migrated, archived or deleted.

 

12 · Solution

How do CHRONOS and IPM replace legacy systems?

The CSP Manufacturing OS brings together process data, quality assurance, worker guidance and audit proof archiving on a common data basis. Two components are decisive for replacing a legacy system, because they separate the two types of data that are mixed in the legacy system.

Contribution of the components to replacing legacy systems

Component Takes over Result
IPM process data management the active process and quality data The business function of the legacy system continues in a structure that can be connected
CHRONOS archiving the historical data that only needs to be retained Data remains retainable, deletable on time and provable, without the legacy system

Export from the database

CHRONOS extracts data directly from the database of the legacy system, even if the original application no longer runs.

Open archive format

The data is stored in a format that remains readable regardless of database version and application.

Evaluations in the archive

A reporting framework delivers evaluations directly on the archive data, without access to the source database.

Without an IT ticket

Fine grained permissions give business departments direct access to their archive data.

A publicly documented example is the residual administration of Anton Schlecker e.K.i.I. According to Computerwoche, CSP prepared seven systems for shutdown there, including Navision, a heavily customised AS/400 system, an intranet and a Teradata data warehouse. A separate database archive was created for each system.

The Austrian Institute of Technology compared CHRONOS with SIARD in a study on digital long term preservation for the use cases database decommissioning, ongoing and partial archiving and application retirement. In manufacturing, the BMW Group archives process data from its plants with CHRONOS at monthly intervals, according to a published case study. Another project is described in the KLS Martin Group success story. What matters when choosing archiving software and a partner is covered in the article Choosing software for audit proof archiving.

Next step

Shut down legacy systems, keep the data

Talk to us about your legacy system. Together we will work out which data belongs in the archive.

 

FAQ

Frequently asked questions about legacy systems

What is a legacy system?+

A legacy system is an outdated but still business critical software application whose maintenance, further development or integration is only possible with considerable effort. What matters is not its age, but the ratio of importance to limited maintainability. In manufacturing, this typically affects process databases, older MES or CAQ applications, proprietary machine data acquisition and in house island solutions.

How do you replace a legacy system?+

In five stages: complete inventory of data, users and interfaces, classification of every data category into migration, archiving or deletion, migration and archiving with a test run and business acceptance, parallel operation with a fixed end date and finally a controlled shutdown with a closing report. Active data moves to the successor system, the history moves to an audit proof archive.

May a legacy system be shut down while retention periods are still running?+

Yes, if the data subject to retention has first been transferred completely and in a machine evaluable form to an archive. The retention obligation applies to the content, not the application. In the first five calendar years after the system change, the archive must allow evaluations equivalent to access to the legacy system. After that, under § 147(6) of the German Fiscal Code (AO), a machine readable and evaluable data carrier is sufficient, provided no tax audit has begun.

Is a backup enough to secure legacy data in the long term?+

No. A backup is used for the technical recovery of a system and is tied to its database version and application. Without the original software, the information often can no longer be interpreted. The German GoBD require data to be available and machine evaluable for the entire retention period. Only an archive that is readable independently of the source system can do this.

How can legacy data be read if the software no longer runs?+

As long as the database is still accessible, the data can be exported directly at database level without starting the original application. It is essential to also secure metadata, table relationships and code lists so that the data remains understandable later. Holdings on tape archives and old export files also belong to the legacy system and must be included in the inventory.

Korbinian Hermann
CEO, CSP Intelligence GmbH
Responsible for strategy and innovative software solutions for the manufacturing industry.

RELATED ARTICLES